Constant Voltage

ELV-10

ELV-10

LED Constant Voltage Drivers
Features
• High reliability, low cost
• 100% full load burn-in test
• Enclosed case with potting, IP67
• Protection: short circuit/overload
• Warranty: 2 years
Specification
Part Number ELV-10CV-5 ELV-10CV-12 ELV-10CV-15 ELV-10CV-24  
Output DC Voltage 5V 12V 15V 24V  
Rated Current 2A 0.83A 0.67A 0.42A  
Current Range 0~2A 0~0.83A 0~0.67A 0~0.42A  
Rated Power 10W 10W 10W 10W  
Ripple&Noise 300mVp-p 300mVp-p 300mVp-p 300mVp-p  
Voltage adj Range 4.5~5.5V 10.8~13.2V 13.5~16.5V 21.6V~26.4V  
Voltage Accuracy ±5% ±5% ±5% ±5%  
Linear Adjustment Rate ±1% ±1% ±1% ±1%  
Load Regulation ±2%
Setup & Rise time 2000mS, 50mS/ rated load
Hold time(Typ)  16mS/ rated load
Input Input Voltage 100~240VAC
Frequency 47~63HZ
PFC(Typ) PF≥0.52
Efficiency(Typ) ≥71% ≥77% ≥81% ≥81%  
AC Current 100VAC 0.2A
240VAC 0.1A
Inrush Current(Typ) 40A/230VAC cooling start
Protection Over Load 110~250% rated, can be automatically restored after abnormal condition removed
Short Circuit Auto-protection when short circuit, can be automatically restored after abnormal condition
removed
Environment  Working Temperature -20℃~+50℃@100% load,+60℃@60% load 90VAC@80% load
 Working Humidity 20~90%RH
 Storage Temp  -20℃~+85℃
 Storage Humidity 10~95%RH
Temperature Factor ±0.03%/℃(0~50℃)
Vibration Resistance 10~500Hz,2G,10min/cycle,60min for X、Y、Z
Safety Safety Requirement Design based on UL1310
Withstand Voltage I/P-O/P:3.0KVAC
Insulation Resistance I/P-O/P:100MΩ/500VDC
EMC Design based on GB17625.1; EN55022,GB9254 ; EN61000-3-2,-3
Harmonic Current Design based on GB17625.1; EN61000-3-2,-3 Limit requirements
EMS Design based on EN55024 ; EN61000-4-2,3,4,5,6,8,11
Others Lifetime 100,000 hrs
Dimension 130*25*22mm(L*W*H)
Note * In order to prolong the service life, suggest to leave 30% of the allowance when loading. For example: equipment requires for 100W, we should choose not less than 130W power supply.
* The ripple test method of switch power supply: Test with 20 MHZ oscilloscope on the output terminal, the ground wire length of oscilloscope is not more than 12 mm, parallel 47 uF electrolytic capacitor and 0.1 uF high-frequency capacitance at the input of oscilloprobe.
* All the electrical performance testing are completed in 25 ℃ environment.